  • Specification
Measurement DO value in water
Measure range 0~20.00mg/l
Resolution 0.01mg/l
Temperature range -20~60°C
Type of sensor Galvanic Cell sensor
Measuring accuracy <0.5mg/l
Output mode RS485 port*1
Communication protocol Compatible with standard MODBUS-RTU protocol
Communication mode RS485  9600,8,1,N  (by default)
ID 1~255 Default ID 01 (0x01)
Fixing method RS485 remote setting calibration and parameters
Power supply mode 12VDC
Power consumption 30mA @12VDC
 
  • Introduction
  • Intelligent module communication protocol Introduction
Communication port: RS485 Port setting: 9600,N,8,1 (by default) Device address: 0x01 (by default) Protocol specifications: Modbus RTU Commands support: 0x03 read register 0X06 write register| 0x10 continuous write register   Information frame format
0x03 read data [HEX]
01 03 ×× ×× ×× ×× ×× ××
Address Function code Data head address Data length Check code
0x06 write data [HEX]
01 06 ×× ×× ×× ×× ×× ××
Address Function code Data address Write data Check code
Remarks: The check code is 16CRC with low byte ahead.
0x10 Continuous write data [HEX]
01 10 ×× ×× ××××
Address Function code Data address Register number
×× ×× ×× ×× ××  
Byte number Write data Check code  
  Format of register data
Address Data name Switch coefficient Status
0 Temperature 0.1°C R
1 DO 0.01mg/L R
2 Saturability 0.1%DO R
3 Sensor. null point 0.1% R
4 Sensor. slope 0.1mV R
5 Sensor. MV 0.1%S R
6 System status. 01 Format 4*4bit 0xFFFF R
7 System status.02 User command address Format: 4*4bit 0xFFFF R/W
Remarks:Data in each address is a 16-bit signed integer, the length is 2 bytes. The real result=Register data * switch coefficient Status:R=only read; R/W= read/write

Hot Products

SUP-R4000D Paperless recorder

SUP-R4000D Paperless recorder

SUP-EC8.0 conductivity meter

SUP-EC8.0 conductivity meter

SUP-PX400 Pressure transmitter

SUP-PX400 Pressure transmitter

SUP-LUGB Vortex flowmeter wafer installation

SUP-LUGB Vortex flowmeter wafer installation

SUP-RD902 26GHz Radar level meter

SUP-RD902 26GHz Radar level meter

SUP-RD902T 26GHz Radar level meter

SUP-RD902T 26GHz Radar level meter

SUP-LDG Remote type electromagnetic flowmeter

SUP-LDG Remote type electromagnetic flowmeter

SUP-PH8.0 pH ORP meter

SUP-PH8.0 pH ORP meter

SUP-PX261 Submersible level meter

SUP-PX261 Submersible level meter

SUP-DO7016 Optical dissolved oxygen sensor

SUP-DO7016 Optical dissolved oxygen sensor

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours